This appliance should give many years of trouble free use, when installed to the specifications contained in this document. The Bosch Story Bosch Thermotechnology has year, Bosch provide hot Extensive research. Adjust appliance with only one tap operating.Warning If the appliance does not operate, burns with yellow flame, leaks water or a gas smell is evident, turn off and contact the local gas authority, the manufacturer or an authorised service person. Model BOSCH 10H BOSCH 13H BOSCH 16H Minimum Inlet Pressure for 60 kPa 100 kPa 130 kPa maximum water flow Minimum Inlet Pressure for. Anti clockwise to decrease minimum burner pressure. Model BOSCH 10H BOSCH 13H BOSCH 16H Burner Pressure LPG 0.64 kPa. Do not install this water heater with any modification or alteration. Do not install this water heater indoors or in an enclosed space.Claims for warranty will only be accepted upon suitable proof of purchase submitted to Robert Bosch (Australia) Pty. Ltd. Or an approved Bosch Service Agent authorised to carry out warranty repairs. Installation should be pretty straightforward and the manual's not that in depth. There are however some sections on adjusting the gas and the like that you might want to read over.Login to post Now if needed clean over the whole unit with compressed air to spruce it up and reduce fire hazard or if your diy then it's nice to clean things before working on them imo. Don't ask me what all that would cost. You don't need to mess round with the gas side that's all fine. Now here's what you do to fix em, this is for a Bosch Hydropower 10H but I assume it probably applies to the other hydropower models too.Search: GWH 715 ES manual.pdf Adding.pdf to search parameter helps locate manuals.
Sell sheet with venting overview, technical and product specs: Manual for ES high altitude, with installation, error codes and troubleshoot: I cannot find a service manual, or service bulletins: The suspect is probably gas supply, gas valve, or gas related part inside tankless unit. Before calling service technician, open following link for Bosch tankless troubleshooting resources, including Bosch contact information, typical manuals, error codes, tech support, parts, fuel-saver calculator, service bulletins, water heater forum, fixya links, disclaimers, and links for finding service technician. Read manual cover to cover, make sure tankless receives yearly maintenance as outline in manual. Add a comment with your experience so others with same-similar problem can benefit. Also take advantage of fixya expert assistance live. For a price, expert works with you while you work on water heater or any do-it-yourself project. Fixya is always less expensive than a service call.The gas is turned on. Just moved into this house so new to the machine with no manual. Comes up with. Read manual cover to cover, make sure tankless receives yearly maintenance as outline in manual. Fixya is always less expensive than a service call.The unit suddenly has no spark.I have taken off the little generater cap and thouroughly cleaned it and the internal turbine. With no improvement. All. Installation should be pretty straightforward and the manual's not that in depth. There are however some sections on adjusting the gas and the like that you might want to read over.What is going on? Answer questions, earn points and help others. I suspect a rubber diaphragm may have a hole in it. Dismantling the lower housing surrounding the diaphragm and the several connecting pipes looks pretty tricky without some guidance. I don't need to dismantle the whole thing, just the lower section under the water flow adjustment knob.
If I can get it apart and it is only a rubber diaphragm that needs replacing then I can do it. If it's anything else it will mean a plumber and probably a whole new HWS -which is fine but I want to try the simple DIY fix first. I note in the current user manual fault options that the Hydro generator should be cleaned. The manual has no reference to this procedure. Can you give me instruction to carry this out. The click click of the starter process is not heard now. I have back flushed the unit which appears to be a temporary solution. I have had three service calls in the last 18 months which have cost me more than half the purchase cost of a new 10H. Your appointed technicians had spent most of the time on their mobile to your Bosch technical line. So please don't send me back to this process. Hope you can help. Sher Like Share More No answers ARJ B. asked 3 months ago HydroPower 10H Hot has decreased by half, and water flow decrease also by half once Technician installed BF 10H Technician has advised property is to old bad luck I am stack with a new system that operates poorly need assistance please Thankyou Like Share More No answers Lara asked 4 months ago HydroPower 10H my system works fine during the day, but at night it is very hard to get the system to work.I have to turn the taps on and off many many times, each time checking to see if it has lit. Eventually it does light up. But this is so annoying. I have skipped having a night time shower for several years, but I no longer have that option. Hoping that this is a simple problem to fix. Like Share More 2 answers mrammelt 4 months ago Get your gas pressure checked. Like Report Lara 4 months ago Thanks, I have had my gas pressure checked, during the day. I wasn't aware that gas pressure would drop at night. Like Report Ash L. asked 5 months ago HydroPower 10H IV just moved into a flat and have no hot water. If pilot light is automatic how do I start it. There is no red or green light on at all.
Like Share More 2 answers mrammelt 5 months ago Turn on the gas supply, water supply and a couple of hot water Fawcett's. When you do have a listen to the unit to see if it's fired up. If not call the real estate agent or owner as it's their responsibility. Like Report Ash L. 5 months ago I turned everything off for hour then turned tap inside on then gas then water and it started straight away thanks Like Report Eddie G. asked 5 months ago HydroPower 10H Hi sometimes with my H10 the main burner won't ignite. The pilot flame ignites every time waters turned on but on occasions the main burner won't work. Gas regulator has been replace recently. Like Share More No answers Graynurse asked 6 months ago HydroPower 10H We have a Bosch 10H it starts off okay but hot water only stays on a few minutes then we have cold for a few minutes then hot water returns unit is only 3 years old Like Share More 1 answer Happy 6 months ago My advice.get a qualified gas fitter familiar with Bosch systems to service the unit and check the water pressure, gas pressure and heat exchanger are functioning properly. 1 like Report Sam A. asked 8 months ago HydroPower 10H Heya, i own a bosch hydropower 10H. As this is a highly unattractive system we wanted to enclose in with lattace. If you are looking to conceal your unit, we suggest that you would need to make the enclosure out of a non-combustible material that is removable for servicing. Also the enclosure would need to be 500mm clearance to flue terminal. If you need any further assistance, please get in touch with us at 1300 30 70 37 any time between 7:30AM and 6PM (AEDT) on a weekday. Like Report Taryn hollitt asked 1 year ago HydroPower 10H How do I light the pilot light. The ignition for this unit is automatic. If the ignition fails to ignite after 20 seconds, this will trigger a lockout mechanism. In this case, we would suggest that you turn off all hot water taps and try again.
If the unit still doesn't work, then isolate the valves at the unit for 20 seconds, then open the valves and retry. If after this, the unit still fails to ignite, please get in touch with us at 1300 30 70 37 any time from 7:30am to 6pm (AEST), so we can refer you to a Bosch qualified technician. Please be advised that we do recommend that our units are to be serviced at least every two years so your unit may be due for a service. Like Report Molly asked 1 year ago HydroPower 10H I bought a couple of these in 2015 for rental properties. The tenants haven't complained about the water temperature but the other day checking a water leak i notice that one of them has nearly rusted away. The other tenant confirmed that his was also rusty but I haven't checked that one. The rust is really bad, all over the unit, it looks like it won't last the year out. I'm not sure how long the warranty is or what I can do about this but surely they are meant to be outside and they were fitted by someone from the Gas Company who never said they needed cover. This range has a full warranty of two years for parts and labour, and further warranty of 10 years for the heat exchanger part only. The level of corrosion within the time frame you are referring to sounds extreme and not normal. Although we do not know the location of your units, installation in areas near ocean or marine environments will cause premature corrosion of surface coatings. As such, we recommend in our product literature to avoid such installations as it is not covered under warranty. If you require any further information regarding our warranty conditions, please don't hesitate to get in touch with our team at our toll-free line 1300 30 70 37 (we are available from 7:30am to 6:00pm Monday to Friday). We also suggest getting in contact with your gas company regarding this issue. Like Report Molly 1 year ago We polished it up and put a wooden cover on it and it is ok now.
We do live near the beach but the heater is on the other side of the building. Ga an company was no help. Unfortunately, the powder coated steel we use in our units can be affected by the salt content in the air of your environment. A slightly unorthodox method to slow down the corrosion would be to coat the unit in fish oil as a preventative measure. It can also be purchased from your local hardware store. As mentioned, it will not stop the rust from coming back, but it can help to slow down the corrosion. Please also be advised that due to safety concerns, we strongly recommend the removal of the wooden cover as it is a fire hazard. Like Report Mike Lee asked 1 year ago HydroPower 10H I live in a retirement unit. My hot water system is located inside the rear enclosed patio. Is this a safety issue. Based on the brief details you have provided, we believe that this may be unsafe and may have the potential to cause personal injury and property damage. It could also be non-compliant and illegal, which also means that any servicing issues will not be carried out. We highly recommend that you get a second plumber to come out and inspect the installation. The plumber can make sure regulations are met in order to give approval for the unit’s installation. Like Report Mike Lee 1 year ago Thank you so much. I can nowspeak with the village manager regarding this issue. Please don't hesitate to get in touch with us if you require any further support. Our team is available from 7:30am to 6:00pm Monday to Friday on our toll-free line 1300 30 70 37. Like Report John F. asked 1 year ago HydroPower 10H I will shortly be purchasing a Bosch 10H as highly recommended by my Plumber. This wlll replace my Bosch 10P which is 20-plus years old. In poor condition and rusty. Overall used to work well. Has now failed. How does the 10P compare with the new 10H model.
The Bosch Pilot uses a traditional standing pilot light while the Bosch HydroPower uses water movement to create its own small voltage to ignite the water heater. Please be advised that if you switch from a 10P to a 10H, you may notice a slight difference in performance. We would not recommend switching from a 10P to a 13H, for example, as there would be a significant difference in performance and hot water delivery. If you have any further questions, please get in touch with us at 1300 30 70 37 any time from 7:30am to 6:00pm (AEST) during the weekday and our helpful team will be able to assist you further. Like Report John F. 1 year ago Much appreciated Robert. Sounds like there have been some improvements between the two models. Due to ProductReview updating its platform, we have missed some questions that were asked. The yellow flame indicates that there may be some blockages in the burner which is causing poor combustion. One of the causes of blockages are insects blocking burner orifices (which cannot be avoided as adequate air flow is required for complete combustion). The unit will need to be cleaned and to minimise the chance of this issue recurring, a surface type insecticide can be used with care though a consultation with a licensed pest controller is recommended. If you have already adjusted your gas and water controls, it could be a gas supply issue. As we do need more details to more accurately troubleshoot your issue, we recommend that you give us a call at 1300 30 70 37. We are available from 8am to 6pm (AEDT) during the weekday. Like Report Mike asked 2 years ago HydroPower 10H My Bosch 10H has no pilot nor hot water this cold morning. How do I ignite it? Like Share More No answers Kyrah-lee L asked 3 years ago HydroPower 10H How to start Like Share More No answers pete asked 3 years ago HydroPower 10H pilot lights up but main heat element does not ignite.If not make sure connections to the battery power pack is ok.
(Its 2 wires in a plug) If connection is ok and no spark battery needs replacing. If you can hear spark (tick tick ) and it does not light there is a small pipe that goes to pilot under peizo (spark igniter). Undo the top of pipe 10mm open end spanner be carefull not to break it. There is a little jet (dont drop it) get the little and blow through it they get clogged. (The jet is about as big as a babys thumb nail silver aluminum) tiny little hole that gets clogged. Other than that I dont know. Like Report Gone a million 3 years ago If the water tap is on an no tick tick tick sparking sound the water powered ignition circut has failed. The price of a call out diagnosis plus return visit and part will almost equal new unit with install. It will also fail again that I promise you. Learn by my own costly mistake. Sorry they are lemons. Buy Rinnai B26. Kind regards Paul 1 like Report ptr asked 3 years ago HydroPower 10H Hi, I have a 10H on our house. Recently the hot water has gone from being really hot to lukewarm. Has anybody got an idea as to why??? Thanks. Like Share More 1 answer Ashy 3 years ago If the flame is yellow and sooting up the heat exchanger it is caused by something inside the burner, probably a mud wasp or spiderweb. Remove burner and clean out any obstructions. Also remove heat exchanger and wash out. Reassemble and it should be fine. Like Report Brenton Carter asked 4 years ago HydroPower 10H hi there I have a bosh10 a well and I have very little water flow at all hot water outlets had pressure checked all good is there a internal filter ?? cheers Like Share More 3 answers JGLS 4 years ago Don't know about internal filter but I had new shower rose in and found TWO water savers in it which made for terrible flow and water going cold. Take them out for starters. If you are happy with a standard temp from all taps move the horizontal flame control to around mid way and the temp control nearer warm than hot.
You will only need to use hot water which saves you money, and pressure should be better with water savers out. Like Report Brenton Carter 4 years ago Hi there jgls all ready removed filters fron shower presure was fine yesterday today its crap cheers fror your helpit says in tthe manual that if slow water pressure at exit points that the filter could be blocked i just dont know where it is Like Report Jeff L 4 years ago There is a little filter. There is a little cream plug held in by a metal u shaped clip. If you turn off the water flow then you can pull this bit out and clean the little plastic filter. We look forward to hearing from you. I can light the flame manually with the water running and it will stay lit, only until that tap is turned off. Regards, Jesse. Like Share More 3 answers Leflee 4 years ago Hi Jesse Without having a look at your unit I am guessing that the Hydro generator is faulty. If not faulty there should be a clicking sound and you should be able to see sparking at the ignition point when the water starts to run. The hydro generator is a replaceable unit in the system. Like Report Nick 4 years ago My system wasn't working. Would only heat up occasionally or not at all. The system is about ten years old. Tried everything short of replacing parts or unit. Then thought about age and weather and, above all, surface corrosion. Got some 1200 grit sandpaper from Bunnings ( a nail buffer would do as well ) and cleaned the sparking point and contact. Now it works like new. It might not work for you but if it does its heaps cheaper than any other way to fix it. Also set the gas quite low. Like Report David C 2 years ago Hi Jesse, did you get this fixed. Whether you love or loath being in the kitchen, our community of reviewers have determined that out of almost 5,000 appliances on ProductReview.com.au, these are the best available! Nathan S. Nov 01, 2019 Best Fridges and Dishwashers in 2020.
These large kitchen appliances are the backbone of your kitchen, meant to last you many years. The initial cost of a fridge or dishwasher is high, so to make sure you're not buying a lemon, here are the best fridges and best dishwashers of 2020. ProductReview.com.au has affiliate partnerships. Swift Service is our emergency hot water solution for you. We strive to make the process from purchase to install to post install service a seamless transaction. Your local hot water plumbers Same Day Hot Water provides hot water solutions in Queensland and Western Australia. The system only ignites when a hot water tap is opened. Once the hot water tap is closed, the system turns itself off. This eliminates the need for a standing pilot light or electricity. Saving energy with hot water on demand as a result. It is suitable for 1 bathroom homes and conveniently provides continuous hot water without a powerpoint or a standing pilot light. All our parts are originally manufactured by Bosch so you can rest assured that they will fit your appliance. All you need is the model number (E-NR). This is usually found around the door area or on the rating plate of the appliance. Just click on the link below to get assistance. Phone: 1300 369 744 24 hours support (Monday to Friday) You need these for product registration and booking your repair service. This is usually found around the door area or on the rating plate of the appliance. Just click on the link below to get assistance. Phone: 0800 245 700 Monday - Friday: 8.30am to 5pm (excluding public holidays) Phone: 0800 245 700. Call Churchlands Plumbing. Our licensed plumbers and gas fitters will provide a free quote over the phone and be out to help you in a flash. Due to having a low MJ rating and Burner pressure the Bosch 10P is a good option in areas with low gas pressures.
Similar to the 10P, the 16P provides an extra 6l per minute and still able to work under low gas pressures No pilot light Their compact design also allows installation flexibility. With a compact, space saving design, they will provide endless hot water With a compact, space saving design, they will provide endless hot water Additional costs will apply if current valves are out of date and need to be replaced (expired valves may void the warranty of the new unit ). Tempering valves must be installed if the change over is not a like for like swap. HydroPower. Installation Manual and Operating Instructions. Read installation manual prior to installation of this unit! Read user manual before putting this unit in operation! Observe the warnings in the manuals! The installation room must fulfill the ventilation requirements! Installation by an authorised person only! Table of contentsWarnings. Warnings in this document are identified byKeywords at the start of a warning indicateThe following keywords are defined and used in this document:Important information. This symbol indicates important informationAdditional symbols. Symbol ExplanationList entry. List entry (second level). Table 1If you smell gas:HydroPower. If you notice dark combustion gases or sooting:Installation, Assembly and ModificationsMaintenanceExplosive and highly flammable materialCombustion air and surrounding airRisk of damage due to operator error. Operator errors can result in injury and damage to property.To be installed and serviced only by an authorised person. The “authorised installing person” is responsible for:Models. CategoryTF (Top Flue). G (Hydrogenerator). TF (Top Flue). Table 3Water filter on the inlet water supply. Economical. Only heating water when required, the Bosch range isVersatile. LPG models are particularly popular in country areas, where. Natural Gas is not available. Low Temperature AreasPackage contents. Gas hot water unit.
DocumentationHydroPower Ignition is exclusive to Bosch - it does not requireHydroPower uses the energy created by the water flow toOnce the tap isHot Water Unit for external wall-mounting only. Available in Natural gas or LP gas. Hydrogenerator produces sufficient energy to ignite andSafety devices. Fig. 1. EXOGEL valve. Low Flow Rates. This gas water heater is designed to operate at a minimum flowThere are various causes of a low flow rate including, but notWater fixtures with a flow rate of 7.5 litres per min for handFailure of the unit to operate correctly due to poor flow rate willHydroPowerTop flue. Front cover. Inspection window. Wall mounting point. Cold water inlet. Gas inlet. Hot water outlet. Dimensions (mm)Dimensions. HydroPowerTemperature limiter. Hydrogenerator. LED (green). LED (red). UnitsDiaphragm Switch. Pilot Solenoid Valve. Ionisation electrode (Flame Rod). Ignition electrode (Spark Electrode)Technical characteristics. Gas Consumption. Nominal Gas Consumption. Supply pressure flowing. Number of injectors. Water data. Maximum permissible pressure (Static)Temperature selector in fully clockwise position. Temperature rise (Above incoming water temperature)Minimum operating water pressureTable 5. Technical characteristics. Units. Temperature selector in fully anti-clockwise position. Temperature rise (Above incoming water temperature). Water flow range (Litres per minute)Minimum operating water pressureNOTICE: Property damage! If the appliance is to be installed on aRegulations. All local by-laws and regulations pertaining to installation andThis appliance must be installed in accordance with the. This appliance must not be installed indoors or in an enclosedDo not install this appliance with any modification or alteration.Failure to install this appliance in accordance with theseDANGER: Explosion Risk!DANGER: Appliance malfunction! This appliance must be installed with noHeat shield.
The installation and the initial startup are toNot suitable for pool, spa pool, or solarNot suitable for commercial boosting of aThis appliance should only be installed inHydroPower. Minimum water supply pressure must meetWater fixtures with a flow rate of 7.5 litresTo reduce the chance of corrosion,All gas appliances require adequate airPest and dirt ingress is not covered by theThis test must beNote: Incorrect pipe sizing or gas supply pressure may causeService calls for incorrect pipeImportant informationIf the unit is to be installedThe preferableHydroPowerComply with the specific instructions for each State. Install the appliance in an outdoor location where it will notInstall the appliance in accordance with the minimumThe gas heater must not be installed over a heat source. Do not obstruct the openings at top, bottom and rear ofMaximum of 2 meters from the ground to the base of theTop and bottom areas must be clear from any obstacles atOpenable Door. Flue terminal. Gas meter. Mechanical air inlet. Electricity meter or fuse box. Openable window. MinimumRef. ItemBelow eaves, balconies and other projections:Combustion gasesFig. 6. Heater mounting. HydroPowerThe gas pressures require setting upon installation.Water connection. Purge the water pipes before connection, because thePressures to complete appliance commissioning.Fig. 7. Water connectionValve, Duo Valve or Non-Return Valve mustIncorrect gas pipe sizing will not be coveredFront cover removal. Gas regulator. The appliance is supplied with a gas pressure regulator alreadyHydroPowerGas pressure adjustment (commissioning) MUST be carriedStatic Pressures should be greater than or equal to the figuresAdjust the appliance regulator to achieve the figures in table 7If the operating inlet pressure cannot be achieved there may beThis must be resolvedMaximum gas flow adjustmentRight (maximum gas flow).Measurements should be made with unitIf possible all other gas appliances (ductedNatural gas. LP gasTable 7Max.
Burner. Pressure (kPa). Table 8. Natural gas. LP gasMinimum gas flow adjustmentBurner pressure adjustmentHydroPowerFig. 12For higher water temperature (Fig. 13). Slide to the right will give higher water temperature but useFig. 13Increases flow and decreases water temperature (Fig. 14). Minimum gas flow adjusting screw. LP gasPressure (kPa). Table 9Conversion to a different type of gas. It is not recommended to convert these units to a different typeFor lower water temperature (Fig. 12). Slide to the left will give lower water temperature and use lessFig. 14Decreases flow and increases water temperature. Regulating the temperature to the minimum required valueThe LED light is not normally visible with the cover on, howeverIf the red LED is flashing this indicates a fault condition andHydroPowerTo ensure ongoing performance and safety, we require theMaintenance must only be performed by aMaintenanceHydroPowerThe following chart offers possible solutionsIn most instances it is advisable to have a technician attend and inspect the appliance. Some further trouble shooting advice may be found at. Problem. Cause. Solution. Fluctuation in hot water temperature. Insufficient flow through the hot waterIncrease water flow by opening multipleIf fluctuation ceases then check forTapware does not give sufficient flowChange tapware to meet requirements. Unit not working. (No Hot Water). Locked out due to failure to ignite. Turn off all hot water taps and retry. The ignition will lock out after 20 seconds If unit still does not work - isolate valves atIf unit still fails to ignite refer to qualifiedUnit not working after change in Gas. Supply (Maintenance work on Mains orAir in gas lines. Turn on hot water tap inside house. Isolate water valve at unit for 20 seconds. Open valve and check if unit lights. Repeat this operation 3-4 times, if unitNot hot enough. Insufficient Natural Gas supply. Requires a service technician to inspectConsumer gas and water controls.
Adjust gas and water controls.Smell of gas. Gas leak.Call your Gas Retailer or a qualifiedTemperature too hot in Summer. Incoming water temperature hasAdjust Water and Gas controls at the unitTemperature too cold in Winter. Incoming water temperature hasAdjust Water and Gas controls at the unitTable 10. Reduced water flow. Insufficient water supply pressure. Dirty taps or mixers. Water valve blocked (filter). Heat exchanger blocked (limescale). Requires a service technician to inspectUnit makes a loud bang when igniting. Explosive ignition is not normalCall a qualified technician. This is normally caused by blockages inOne of the causes of blockages is insectsAll gas appliances require adequate airThe ingressThe unit will needTo minimise the chance of the issueIsolate the valves to the unit and sprayLeave for 15 minutes before turning hotWater takes a long time to reach hot taps. Location of unit. If the unit is located a long way from theAs the hot waterOpen hot tap to full to increase flow rateTable 10Environmental protection is a basic company strategy of. Bosch. The quality of our products, profitability andOld appliances. Old appliances contain valuable materials that should bePackaging. We participate in the recycling program of the respectiveAll of our packagingHydroPowerAll Bosch water heating appliances are constructed from highWhile Bosch water heaters are warranted againstIn the case of the waterIn areas of Australia and New Zealand where water may beWhere uncertainty exists concerning water quality, intendingWater quality table. Maximum levelsSaturation. Index(LSI). TotalHydroPowerRobert Bosch (Australia) Pty Ltd. Thermotechnology Division. Voluntary Repair or Replacement Warranty. All Bosch products are carefully checked, tested and certified to Australian and New Zealand standards. Important Note: Mandatory Australian Consumer Law statement. If you have purchased your product in Australia, you should be aware that.